The Fluke 360

Fluke 360, a rugged and accurate solution for leakage current measurement

 Ideally designed for non-invasive checks of insulation condition,

 the Fluke 360 allows you to perform tests without powering down the installation or disconnecting equipment - saving you time, without compromising on quality or safety. 

The unique jaw design of the Fluke 360 eliminates the influence of adjacent current conductors, and minimizes the effects of external magnetic fields, even at low currents.

This allows you to perform accurate and reliable tests in today’s crowded electrical environments.
 The tough and high-quality clamp design of the 
Fluke 360 guarantees high stability for long-term repeatability. 
Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion
Broad range of measurement, from 1 µA up to 60 A, for all installation needs Advanced shielding to ensure accurate results when measuring near other conductors The high durability clamp construction can withstand over 50,000 operations - added ruggedness that extends the life of your clamp.
 Easy-to-carry, pocket-sized clamp with wide 40 mm (1.5 in) jaw size Handy "Display-Hold” button for capturing readings in hard- to-reach places Auto power-off, with warning buzzer, saves battery life Conformance to IEC1010 and EMC standard for confident measurements Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances special

Features IEC 61010 and EMC Conformance High Accuracy 

IEC 61010 safety features including a tactile barrier and special jaw design

provide the user with confidence when making measurements in hazardous voltage areas. 
Conformance to EMC standards ensures high reliability
 through reduced susceptibility to electromagnetic interference.


Advanced jaw design means that the Fluke 360 accuracy is little affected by external magnetic fields even at low currents. 


Typical external current rejection is 200,000:1 The Fluke 360 also meets the latest safety standard VDE0404-4 and the new VDE0702 requirements Method of detection 

Display Mean value Digital display: 3200 counts Bar-graph display: 32 segments,

 LCD 2 times/second (Digital display), 12 times/second (Bar-graph display) 

Auto-range Measurement cycle

 Range switching Ambient temperature and humidity 0 °C to 50 °C, 80 % 

RH or less (no condensation) 

Temperature coefficient 0.05 % of range/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A) Influence of external magnetic field

Influence of conductor position

 Circuit voltage 0.0005 % typical 1 (on current value of adjacent cable)

 Within accuracy ≤ 300 Vrms Safety standard EN 61010-1, EN 61010-2-032. 300 V CAT II, Pollution Degree 2 3.7 kV ac for one minute 

Withstanding voltage Battery type 1 x 3 V

 Lithium battery (button cell) CR2032 Approx. 90 hours (when continuously used) Approx. 10 minutes Battery life Auto power-off 

Diameter of measurable conductor 

Weight 40 mm max. 200 g (441 lb) 

Dimension 176 mm x 70 mm x 25 mm (6.9 in x 2.8 in x 1 in) 2000 m (6,562 ft